Please enable JavaScript to view this site.

MaxxECU online help

Navigation: MTune Settings > Advanced

Filters/error codes

Scroll Prev Top Next More

Filters/error codes

 

Option to filter ("slow down") engine data values before they are used for internal calculations.

Note: Higher value = more filter.

 

MAP filter level

MAP value filtering level.

 

RPM filter level

RPM value filtering level.

 

TPS filter level

TPS value filtering level.

 

Advanced settings

 

debounce digital inputs

Used to remove very short extra pulses before or after an actual input signal to avoid triggering twice. Should be set to on.

 

Disable EMI warning

Discard warnings for high interference levels.

See, noise and interference problems.

Note: We recommend not to disable this feature, correct the problem!

 

Disable 12V2 warning

Disables warning for missing 12V2 power supply.

12V2 (in harness 3) input should be connected to +12V when more power hungry features are used in harness 3 and 4.

Note: Only visible on MaxxECU PRO

 

hide some trigger errors

no - All trigger errors will be showed.

Hide some trigger errors - Option to "hide" some trigger errors that might occur "sometimes" and not repeatedly on most trigger systems.

 

 

 

Examples

 

clip0869

Option to hide trigger errors that might occure during engine start and shutdown, and errors that might happen "sometimes" and not repeatedly.