Please enable JavaScript to view this site.

MaxxECU online help

Navigation: Advanced > Boost control

Boost control: Open loop (simple)

Scroll Prev Top Next More

Requires an output to be enabled as Boost solenoid (simple/open loop)

 

 

Boost control (simple/open loop)

 

Boost control mode

Specifies how the function is enabled.

Disabled.

ENABLED.

Enabled with digital input - Enabled when the digital input function Boost Control Enable is active.

 

Activate above MAP

Specifies the MAP value where the control will be active, default 120kPa.

Note: Before MTune 1.145, the MAP value had to exceed 120kPa to actually pulse the output.

 

target tables

Specifies the target tables to use for open loop boost duty.

Single table - One boost duty table available.

Dual table (switch activated) - Two boost duty tables available, switchable by triggering the digital input function Boost target switch (use table 2).

Triple (switch activated) - Three boost duty tables available, switchable by triggering the digital input function Boost target switch (use table 3).

Triple (controlled from MDash) - Three boost duty tables available, changeable in the MDash android app, see MDash boost selector.

 

TPS adjustments

Enables a table to adjust boost duty by TPS, mostly used to lower boost duty on lower TPS positions.

 

Gear adjustments

Enables a table to adjust boost duty by gear, requires a wheelspeed sensor. Used to lower boost duty on lower gears.

 

Extra adjustments table

Enables an user defined table, to adjust boost by anything you want.

 

Solenoid

Specifies the boost solenoid used (presets for solenoid frequency). If your solenoid is not available in the list, please select User defined and the frequency settings will be available here below.

 

Solenoid frequency

Specifies the boost solenoid frequency if a User defined solenoid selected above.

 

 

Boost solenoid duty table X

 

Description

Name of the boost level, you can name this to whatever you want, if using MDash boost selector, this name will be available in MDash in the boost selector switch.

 

Boost duty

The open loop base duty table, if you don't have any compensations enabled, this table outputs the duty in the table at the specified frequency.

 

 

 

Which boost target is selected?

clip0645

In MaxxECU RealTime Data, Boost control, Active boost table.

 

clip0646

In the boost settings, an -active- text will be visible right next to the active boost level.

 

 

Example

clip1750

Simplest possible boost control solution. Just a plain solenoid duty (%) table with load and RPM as axis.

 

Note: When using MDash boost selection function, the "Description" name entered here is also visible in MDash app to be viewed.

 

 

Add more functionality to your open loop boost control:

TPS adjustment.

Gear adjustment.

Extra table adjustment.