Can be used to trigger certain input functions based on internal/external conditions.
Function name
Description
Name of the function.
Condition
Condition A/B/C/D/E
Condition X for activation of the function.
output configuration
output function
Condition(s) to be used for this internal function to be triggered.
turn on delay
Specifies a delay time (in seconds) to be used when condition (s) are active before actually triggers this function.
turn ofF delay
Specifies time (in seconds) to delay a active function before actually disabling the function.
output
•Normal.
•Inverted - Inverts the output, if condition are active, the actual output state is inactive.
•latch, push: on, push: off - Push to activate the output state, push again to deactivate.
•latch, push: on, long push: off - Push to activate the output state, long push again to deactivate.
output flash
Flash feature of function with different options:
•Slow flash when output active
•Fast flash when output active
•Slow flash when output inactive
•Fast flash when output inactive
Note: The flash functionaility is mostly used when light bulbs/LEDs are wired to physical output.
INputs to control
Selects which MaxxECU digital input function to be triggered by the conditions.
Note: as of MTune 1.107 two inputs can be controlled by the same internal output function.
In the above example we will trigger the input function Start logging when condition (A and B) or C is active and log for 120 seconds. In other words: When engine is over 3000RPM AND over 0.4bar (5.8 PSI) of boost, MaxxECU starts to log. Also, automatically starts to log upon errors.
Note: Start logging based on engine conditions might be easier to setup at set RPM and TPS function found in the Configuration --> ECU Logging settings.
The above example will trigger the anti-lag and disable traction control input functions when the physical digital input 1 is active.
The above settings will change to secondary RPM limiter and disable traction control features when Bluetooth input swith 1 AND the active boost level 3 is activated.
Note: Bluetooth input switches can directly activate digital input functions without the usage of this internal output function.