Nitrous protection
min clt
Minimum CLT for the system to activate.
Disable nitrous at rev-limit
Disables the nitrous before hitting the rev-limiter. Highly recommended....
disable nitrous at fuel/ign cuts
Disable the nitrous when fuel or ignition cuts occur. To help prevent backfires. Recommended for street setups. Experienced tuners may want to turn this off in drag racing setups. For example traction control or power management system activation.
Safety reactivation delay
Minimum time from the safety system closes the solenoids to the solenoid(s) are allowed to open again (after the safety conditions are reached again).
Nitrous EGT protection
EGT protection enable
Aborts the nitrous when the exhaust temp(s) gets to high.
Max temperature
Max temperature to activate EGT protection.
activation delay
Specifies the activation delay after EGT highest temperature has been reached.
Nitrous Lambda protection
Lambda protection enable
Aborts the nitrous function when the engine runs too lean.
max lambda
Max lambda to be reached.
activation delay
Specifies the activation delay after highest lambda has been reached.