Please enable JavaScript to view this site.

MaxxECU online help

clip1521

PDM20 wiring instructions in PDF format.

 

 

Note: Each PDM output pin can handle Max 10A, if you need more current, parallel wire the cables and select the same output function in MTune PDM output config.

 

PDM20 Max current (A)

Output

Current (A)

Note

Out 1

25A

+12V output

Out 2

25A

+12V output

Out 3

25A

H-bridge output (+12V or GND)

Out 4

25A

H-bridge output (+12V or GND)

Out 5

25A

H-bridge output (+12V or GND)

Out 6

25A

H-bridge output (+12V or GND)

OUT 7

25A

H-bridge output (+12V or GND)

OUT 8

25A

H-bridge output (+12V or GND)

OUT 9

15A

+12V output

OUT 10

15A

+12V output

OUT 11

15A

+12V output

OUT 12

15A

+12V output

OUT 13

15A

+12V output

OUT 14

15A

+12V output

OUT 15

8A

+12V output

OUT 16

8A

+12V output

OUT 17

8A

+12V output

OUT 18

15A

+12V output

OUT 19

8A

+12V output

OUT 20

15A

+12V output

Max total current: 230A

Note: if total current exceeds 160A, the PDM20 needs to be mounted on a bigger heat conduction surface.

 

 

PDM20 Connector 1

Position

Connector 1 (34-pin)

Note

1

Out 1

Default ECU power

2

Out 2


3

Out 3


4

Out 4


5

Out 5


6

Out 6


7

OUT 7


8

OUT 8


9

OUT 19


10

OUT 1

Default ECU power

11

OUT 2


12

OUT 3


13

OUT 4


14

OUT 5


15

OUT 6


16

OUT 7


17

OUT 8


18

OUT 1

Default ECU power

19

OUT 2


20

OUT 3


21

OUT 4


22

OUT 5


23

OUT 6


24

OUT 7


25

OUT 8


26

CHassie GND


27

CHASSIE GND


28

CHASSIE GND


29

CHASSIE GND


30

CHASSIE GND


31

OUT 20


32

OUT 20


33

OUT 18


34

OUT 18


 

 

PDM20 Connector 2

Position

Connector 2 (26-pin)

Note

1

OUT 9


2

OUT 10


3

OUT 11


4

OUT 12


5

OUT 13


6

OUT 14


7

OUT 15


8

OUT 9


9

OUT 10


10

OUT 11


11

OUT 12


12

OUT 13


13

OUT 14


14

AIN RAW 1 (0-24V)

Default key_in. Can be used as DIN switch with pullup enabled (15kohm to vBat).

15

AIN RAW 2 (0-24V)

Can be used as DIN switch with pullup enabled (15kohm to vBat).

16

AIN RAW 3 (0-24V)

Can be used as DIN switch with pullup enabled (15kohm to vBat).

17

AIN RAW 4 (0-24V)

Can be used as DIN switch with pullup enabled (15kohm to vBat).

18

CAN L


19

OUT 16


20

AIN RAW 5 (0-24V)

Can be used as DIN switch with pullup enabled (15kohm to vBat).

21

AIN RAW 6 (0-24V)

Can be used as DIN switch with pullup enabled (15kohm to vBat).

22

AIN RAW 7 (0-24V)

Can be used as DIN switch with pullup enabled (15kohm to vBat).

23

+5V SENSOR SUPPLY


24

SEnsor GND

To be separated from MaxxECU Sensor GND

25

CAN H


26

OUT 17


 

 

Part

AMP/Superseal 1.0

Quantity

Connector 1 (34-pin)

4-1437290-0

1

Connector 2 (26-pin)

3-1437290-7

1

Terminal / pin

3-1447221-3

58

 

 

clip1521

PDM20 wiring instructions in PDF format.