When this input is active, engine will not start or will be stopped if running.
Can be used as an anti-theft function or safety function.
1. Configure an oil pressure sensor on an available 0-5V AIN channel.
2. Create an internal output, set your conditions and activate the Stop engine/prevent start digital function.
Note: Remember to set all conditions so it wont trigger during crank, which might prevent the engine from starting.