When this input is active, engine will not start or will be stopped if running.

Can be used as an anti-theft function or safety function.

 

 

Examples

 

Shutdown engine if oil pressure i dropped below 800RPM

clip0643

1. Configure an oil pressure sensor on an available 0-5V AIN channel.

 

 

clip0644

2. Create an internal output, set your conditions and activate the Stop engine/prevent start digital function.

 

Note: Remember to set all conditions so it wont trigger during crank, which might prevent the engine from starting.